Hello
 I am a repair tech for medical equipment and am needing to make some
test boxes for simple location of the number of a wire that has been
cut off in a harnesses with as many as 256 wires in them.

These harnesses have a plug on one end and the cut-off unlabled wires
at the other end . Up untill now I have used what is called a "light
box" these boxes have a plug to plug the harness into.. 128 or 256leds
on them and an internal battery and a lead so that when you touch one
of the wires with the lead one of the leds will light showing which pin
on the plug is associated with that wire (each wire is then labled)

Now with what I would like to build.
Since you have to look at these wires through a microscope it is very
time consuming to look up from the scope to see the led every time.
What I would like to do is replace these leds with something that
announces the number like "21" "102" "128" etc. with a voice this
would make labeling much faster.
Does anyone know of a pre-made IC? or EEprom? that would have 128 or so
individual areas that could store the voice message for the number and
be random accessed. would it need some sort of special trigger? As im
sure you can tell my knowlege is limited in this area, I am just
starting to work on this project and anyones ideas would be greatly
appreciated.



Relevant Pages

  • Re: 2000 Miata runs intermittently terrible
    ... wires and plugs it still happened. ... (Or replace the coil pack, plugs, and wires.) ... The first O2 sensor may also be bad. ... Use NGK "blue" plug wires. ...
    (rec.autos.makers.mazda.miata)
  • Re: sureshot
    ... match units from this era were wired the same and, since they plug in, ... and tell me what the color of the wires are that are soldered onto the ... The wires on the disc to the male end jones plugs ... making the assumption that the 0-9 is wired the same for the relay you ...
    (rec.games.pinball)
  • Re: Confused about home inspection report
    ... The breakers at the interior electric panel in the hall area have ... Some home inspectors will right this up as a problem based on the size of the wires that supply the unit. ... Motor loads often have breakers that are too large to protect the supply conductors from overload because that is done by the overload protection at the motor itself. ... There is no plug in the attic space near the a/c unit. ...
    (alt.home.repair)
  • Re: Should I PID my Heat Exchanger?
    ... > in spending the money. ... I made the mistake of posting an article suggesting ... One part of the solution is a modified plug and your use of a Hoppy ... wires might be difficult without a grounded conductor. ...
    (alt.coffee)
  • Re: wanting jukebox help
    ... em pinball wrote: ... i need the little 4 prong plug assemblys to redo them ... If so it would be a lot easier to splice the wires (& they are ... AMIs are notorious for having brittle lamp cord wiring - it must all be replaced to avoid shorts or fires... ...
    (rec.games.pinball)

Quantcast