Re: LDO AC analysis
jutek wrote:
> hello
>
> could you tell me how to do AC open loop LDO simulation properly?
>
> how the inputs should be polarized when i open the loop to pass device
> give me the current i want to.
>
> when i do transient and op analyses, everything is ok. vref is connected
> to - and output voltage through feedback divider to +.
>
> i want the AC simulation to be adequate TRANSIENT simulation, to be sure
> how gain, UGF and pole/zero position influence transient response
>
> thanks in advance
>
> regards
http://www.nbp.pl/en/banknoty/banknoty/pln20.htm
.
Relevant Pages
- Re: Why AC analysis result doesnt agree with the transient result
... AC simulation results depend on the operating point. ... During transient analysis, the signal swing may be large enough to shift the operating point, thus ... In order to get the same results during AC and transient, the different stages of your amplifier ... would need to be perfectly linear over the whole dynamic range, which is probably not the case. ... (comp.cad.cadence) - Re: Why AC analysis result doesnt agree with the transient result
... AC simulation results depend on the operating point. ... During transient analysis, the signal swing may be large enough to shift the operating point, thus ... In order to get the same results during AC and transient, the different stages of your amplifier ... would need to be perfectly linear over the whole dynamic range, which is probably not the case. ... (comp.cad.cadence) - Re: Problem with Spice - it wont allow me to change bounds of graph
... The circuit appears to ... >> simulation and AC simulation, ... >> once the transient simulation settles at a believable ... stable and predictable gain versus operating point. ... (sci.electronics.design) - Re: pss: "Time steps are continuously to be extremely small."
... Now pss refuses to converge. ... >simulation shows a nice periodic waveform with a period of about 1ns. ... initial transient from the PSS. ... (comp.cad.cadence) - Re: calculating a config word during operating point analysis
... and have had difficulty giving comp.cad.cadence my normal level of attention. ... >> since this is the DC that preceeds transient etc. ... >simulation, then "static" will not be run? ... (comp.cad.cadence) |
|