Re: LM336 vs. LM336B ?
- From: clicliclic@xxxxxxxxxx
- Date: 17 Sep 2005 11:37:49 -0700
Roger Hamlett schrieb:
> "Andre Majorel" <cheney@xxxxxxxxxxxxxxx> wrote in message
> news:slrndil386.s25.cheney@xxxxxxxxxxxxxxxxxxx
> > What is the difference between the LM336 and LM336B ? I can't
> > find any on the data *** I have doesn't show any and yet
> > Farnell carries both (at very different prices).
> >
> > Thanks in advance.
> The standard National data ***, has two columns in the electrical
> characteristics section, one labelled 'LM136A/LM336A', and the other
> 'LM336B'.
This should probably read LM136A/LM236A. The LM136 has an operating
temperature range from -55°C to +150°C, the LM236 from -25°C to
+85°C.
> The B has slightly worse tolerance on the initial reference voltage, but
> about twice as good temperature stability.
>
> Best Wishes
The LM336 is specified at (2.49 +/- 0.10)V at 25°C, and the LM336B at
(2.49 +/- 0.05)V, which is twice as good. Between the two, there is no
difference in temperature stability. The stability of the LM136 and the
LM236 is worse because it refers to a larger temperature range.