Re: High current discharge from capacitor

From: Jonathan Kirwan (jkirwan_at_easystreet.com)
Date: 08/07/04


Date: Sat, 07 Aug 2004 10:09:33 GMT

On Fri, 6 Aug 2004 20:12:20 +0100, "markp" <map.nospam@f2s.com> wrote:

>> Sounds kind of like an "all-fire specification." Could it be a 'squib' to
>> ignite something?
>>
>
>Not ignite, melt. It's a gas release plug.

So, if you delivered the energy over a longer time period, conduction would
prevent it from always reaching the required temperature?

...

Capacitive discharge into an R isn't going to supply a constant 28V, you know.
The V will vary as energy is delivered. And the total energy as a function of
time is:

              _ t
         1 /
  E(t) = - * | [V(t)*V(t)*dt]
         R _/
           0

Substituting and solving for t yields,

  t = (1/2) * R*C * ln( C*V^2 / (C*V^2 - 2*E) )

If you try this equation with E=84Joules, V=28Volts, and C=540,000uF, and
R=2Ohms (rounded up) you'll see that it won't deliver 84 Joules in .2 seconds.
Even with over 210 Joules sitting on it, it cannot pump out 84 Joules into 2
Ohms in under .2 seconds. Upping the C value, even to 4F, won't help either.

Upping the voltage to 45V and using C=100,000uF, it takes .177 seconds to
deliver the 84 Joules into 2 Ohms. Can you accept 45V?

Sizing the cap on the basis of specifying that there be no more than 20% drop in
.2 seconds, doesn't mean that it will actually operate that way. The 20% drop
figure is made up and the .2 seconds is a requirement, but these don't have much
to do with what the capacitor and heater *will* do. So sizing a capacitor on
these assumptions, using C=I*dt/dV, won't calculate something that can actually
deliver the energy in the time you specified.

Note in the time equation above that C is both inside the ln() function as well
as outside, while V is only inside the ln() function. This means that if you
reduce C, but increase V to compensate so that you have the same stored energy,
the time to deliver the energy will actually be faster -- even though the stored
energy is just the same either way. For delivery speed of a given amount of
energy, you want to store it on a smaller C and with a larger V.

I decided to try out the energy calculations because I just didn't feel
comfortable with the glib 530,000uF to 540,000uF calculations.

Jon



Relevant Pages

  • Re: "cheesedog" 7-15-06 Greatwoods, MA review
    ... and vibe of last years stop in this venue. ... I liked the acoustic opening set as it forces Kang to play acoustic mandolin. ... I agree they never approached the energy level of last year's Big Summer Classic. ... Weir's delivery so hugely misses the mark with repect to the emotional qualities penned by Hunter and delivered by Garcia, that my stomach was churning by the end. ...
    (rec.music.gdead)
  • Re: High current discharge from capacitor
    ... > The V will vary as energy is delivered. ... For delivery speed of a given amount ... but even glib calculations are ok when it makes you realise the ... is governed by the voltage, and the 20% drop in voltage was sugested as ...
    (sci.electronics.design)
  • Re: High current discharge from capacitor
    ... >>The V will vary as energy is delivered. ... For delivery speed of a given amount ... > size of the capacitor needed is at least the size of a very large house ... > is governed by the voltage, and the 20% drop in voltage was sugested as ...
    (sci.electronics.design)
  • Re: Soon to arrive my HDTV
    ... Joules can measure energy dissipated, energy transferred, or energy ... "No wonder he recommends plug-in protectors. ... sprinkler system and garage door opener. ...
    (alt.tv.tech.hdtv)
  • Re: Mounties Electrocute Airline Passenger
    ... If it was across the chest, I can see how the Taser may have ... The energy involved is much ... recommended energy ranges are 200-360 joules per discharge. ... But you do not find pepper spray, wrestling him to the ground, or other methods dehumanizing or hazardous? ...
    (rec.aviation.piloting)