John Smith wrote:
> "Paul Mathews" <optoeng@pioneernet.net> wrote in message
> news:ed443a10.0411221021.6c9a3e4a@posting.google.com...
>
>>My opinion: Run, don't walk, away from any digital scope older than
>>about 6 years, especially HP scopes, and most especially 54100 and
>>54200 series, which are incredibly heavy, noisy, impossible to
>>service, and, just plain obsolete.
>>
>>Tektronix scopes are much to be preferred, but they put out some dogs,
>>too. For the casual user, it's hard to beat the TDS210/220 scopes,
>>which can be found for as little as $500 on ebay, and well worth it.
>>THS720/730 has its place for portable applications, but batteries are
>>lousy nicads, and processor is very slow, meaning that waveform update
>>rate is frustratingly slow.
>>
>>The above mentioned Tek scopes have sampling rates high enough that
>>you seldom have to worry about Nyquist rate, although you must
>>continue to be aware that the sampling rate slows down as you display
>>more time on the screen.
>>Paul Mathews
>
>
>
> Hey, Paul! Thanks for these pointers. This is just the kind of info I need.
>
> Hooha, back to Ebay.
>
> John
>

As an aside I once needed to cobble together an inductor to repair a
cooked smps. The only scope I had access to was a 54600. I did a "splat
test" on the proposed choke, dumping a large charged cap across it and
monitoring the current thru it (10 1R resistors in parallel) and the
voltage across it. I got 2 dots on the screen in single-shot mode - IIRC
the single-shot sampling rate is a miserable 40MSPS or something low
like that. Needless to say the exercise was rendered pointless.

A bit after that I built an RGB-to-PAL modulator, and I wanted to test
it. I used an expensive HP digital scope (a huge thing, 3.5" floppy
etc). No colour burst, even though the scope was 400MSPS or so. So I
used a crappy old analogue scope, and sure enough there it was. I later
saw one of those scopes for sale at tucker for about $10,000 when I
could buy a new TDS224 for $4000.

Cheers
Terry



Relevant Pages

  • Re: Q about DSO (Instek GDS-2102)
    ... Which states that GDS-2102 which claims a 1 GS/s Real Time Sampling ... has only a 100MSa/s per channel on a two channel scope this ... IMHO when the sampling rate is at least ten times the fundamental ... Other than ONE comparison chart, issued by a competitor, what evidence do ...
    (sci.electronics.equipment)
  • Re: Q about DSO (Instek GDS-2102)
    ... has only a 100MSa/s per channel on a two channel scope this ... IMHO when the sampling rate is at least ten times the fundamental ... I think you'll find that the sample rate will mostly be determined by the ...
    (sci.electronics.equipment)
  • Re: Q about DSO (Instek GDS-2102)
    ... Which states that GDS-2102 which claims a 1 GS/s Real Time Sampling ... has only a 100MSa/s per channel on a two channel scope this ... IMHO when the sampling rate is at least ten times the fundamental ...
    (sci.electronics.equipment)
  • Re: Tek 2445 for TDS 1002?
    ... The TDS 1002 scope is virtually the same as the TDS 210 that I "road ... When set for 5 milliseconds per division, the actual sampling rate is only ... The limitation, for the analog scope, is mostly trace width. ... the DSO, it's the number of points they show on the screen, not the ...
    (sci.electronics.design)
  • Re: question about constants in C++
    ... john smith wrote: ... > be variations in the way that they are used, and I am confused as to what I ... scope, but it is a better design to make it part of the class it is ... Jonathan ...
    (comp.lang.cpp)