Re: Delay on a mains-powered relay?
From: Fred Bloggs (nospam_at_nospam.com)
Date: 01/05/05
- Next message: Winfield Hill: "Re: What's inside an analog 4-quadrant multiplier?"
- Previous message: Rene Tschaggelar: "Re: 528MHz clock level conversion"
- In reply to:(deleted message) DaveC: "Re: Delay on a mains-powered relay?"
- Next in thread: Rob Gaddi: "Re: Delay on a mains-powered relay?"
- Messages sorted by: [ date ] [ thread ]
Date: Wed, 05 Jan 2005 13:25:31 GMT
>
> If power fails at the remote site, so does the control circuitry and its
> power. So a traditional delay relay won't work.
>
> The relay, powered by mains, simply opens the wireless sensor's sense circuit
> when power goes away. I just want it to do so after waiting a few minutes to
> see if power comes back on.
The wireless "sensor's sense" ciruit is most likely something with a
weak pull-up of say 100uA, so that shunting the relay input terminals
with C=100uA/(3V/300secs)=10,000uF 10WVDC should get you close:
View in a fixed-width font such as Courier.
+--------[100]--+------->
| |
o | +
/ === to sensor
o | 10,000u
| |
+---------------+------->