Sensing switch closure with & without power applied?
From: DaveC (me_at_privacy.net)
Date: 01/08/05
- Next message: Rich The Newsgropup Wacko: "Re: OT: Wild Weather"
- Previous message: Jim Thompson: "Re: Instantaneous (analogue) compression of speech signals"
- Next in thread: larwe_at_larwe.com: "Re: Sensing switch closure with & without power applied?"
- Reply: larwe_at_larwe.com: "Re: Sensing switch closure with & without power applied?"
- Reply: Joerg: "Re: Sensing switch closure with & without power applied?"
- Reply: Spehro Pefhany: "Re: Sensing switch closure with & without power applied?"
- Reply: Palindr☻me: "Re: Sensing switch closure with & without power applied?"
- Reply: CJT: "Re: Sensing switch closure with & without power applied?"
- Reply:(deleted message) Fred Bloggs: "Re: Sensing switch closure with & without power applied?"
- Reply:(deleted message) Rodney Josey: "Re: Sensing switch closure with & without power applied?"
- Reply:(deleted message) Rich Grise: "Re: Sensing switch closure with & without power applied?"
- Reply:(deleted message) Lionel: "Re: Sensing switch closure with & without power applied?"
- Reply:(deleted message) Roger: "Re: Sensing switch closure with & without power applied?"
- Reply:(deleted message) Dimitrios Tzortzakakis: "Re: Sensing switch closure with & without power applied?"
- Maybe reply:(deleted message) Dimitrios Tzortzakakis: "Re: Sensing switch closure with & without power applied?"
- Reply:(deleted message) John Fields: "Re: Sensing switch closure with & without power applied?"
- Messages sorted by: [ date ] [ thread ]
Date: Fri, 7 Jan 2005 16:02:26 -0800
Switch closure needs to be monitored. On one side of the switch is mains
voltage (120vac); on the other, the load.
Simple enough to monitor the switch's status: when mains voltage appears on
the load side, it's closed.
But how to monitor this switch during a power failure? I'd like to be able to
report to an alarm sensor's input (simple current loop) when this switch
closes, whether mains power is applied to the switch, or power has failed.
When power fails, I could put a simple battery and coil of a l.v. relay
across the switch. But when mains voltage reappears, removing the battery
circuit in time becomes a bit risky.
How best to accomplish this task? Ideas?
Thanks,
-- Please, no "Go Google this" replies. I wouldn't ask a question here if I hadn't done that already. DaveC me@privacy.net This is an invalid return address Please reply in the news group
- Next message: Rich The Newsgropup Wacko: "Re: OT: Wild Weather"
- Previous message: Jim Thompson: "Re: Instantaneous (analogue) compression of speech signals"
- Next in thread: larwe_at_larwe.com: "Re: Sensing switch closure with & without power applied?"
- Reply: larwe_at_larwe.com: "Re: Sensing switch closure with & without power applied?"
- Reply: Joerg: "Re: Sensing switch closure with & without power applied?"
- Reply: Spehro Pefhany: "Re: Sensing switch closure with & without power applied?"
- Reply: Palindr☻me: "Re: Sensing switch closure with & without power applied?"
- Reply: CJT: "Re: Sensing switch closure with & without power applied?"
- Reply:(deleted message) Fred Bloggs: "Re: Sensing switch closure with & without power applied?"
- Reply:(deleted message) Rodney Josey: "Re: Sensing switch closure with & without power applied?"
- Reply:(deleted message) Rich Grise: "Re: Sensing switch closure with & without power applied?"
- Reply:(deleted message) Lionel: "Re: Sensing switch closure with & without power applied?"
- Reply:(deleted message) Roger: "Re: Sensing switch closure with & without power applied?"
- Reply:(deleted message) Dimitrios Tzortzakakis: "Re: Sensing switch closure with & without power applied?"
- Maybe reply:(deleted message) Dimitrios Tzortzakakis: "Re: Sensing switch closure with & without power applied?"
- Reply:(deleted message) John Fields: "Re: Sensing switch closure with & without power applied?"
- Messages sorted by: [ date ] [ thread ]
Relevant Pages
|