Re: Cpacitance or Dielectric Measuring
From: Winfield Hill (hill_a_at_t_rowland-dotties-harvard-dot.s-edu)
Date: 03/04/05
- Next message: Alan Turner: "Re: How to eliminate the DC motor back emf?"
- Previous message: Dave Boland: "Re: SPI unterminated"
- In reply to: Fred Bartoli: "Re: Cpacitance or Dielectric Measuring"
- Messages sorted by: [ date ] [ thread ]
Date: 4 Mar 2005 05:39:00 -0800
Fred Bartoli wrote...
>
> On a question I asked previously, the OP answered with a
> totally unrealistic range:
>
>> Measurement frequency: minimum 5kHz
>> Estimated capacitance: .001pF - 1mF
>> Budget: maximum 5k$
>
> Seems he doesn't know what he's after.
Yes.
BTW, my hp4280A 1MHz C-V, C-t meter measures down to 0.001pF
and can take bursts of high-resolution measurements in 10us.
This capability is for Zerbst analysis, used to determine
minority-carrier lifetime and surface-generation velocity.
Perhaps the O.P. can purchase one of these instruments.
--
Thanks,
- Win
- Next message: Alan Turner: "Re: How to eliminate the DC motor back emf?"
- Previous message: Dave Boland: "Re: SPI unterminated"
- In reply to: Fred Bartoli: "Re: Cpacitance or Dielectric Measuring"
- Messages sorted by: [ date ] [ thread ]