Re: S-parameter test sets
- From: Terry Given <my_name@xxxxxxxx>
- Date: Tue, 28 Jun 2005 14:08:51 +1200
Joerg wrote:
Hello Terry,
and best not to think about how the display appears on the 3577 or 3585.
The 3577 can't do spectrum display. Wish it could, that would free up some lab rack space although its fan creates quite a racket.
Regards, Joerg
not as such, no. But I can do a magnitude-only plot of A (or B, or R). so when considering excitation-and-response, it behaves the same as a speccy with tracking generator.
And it uses the same display module as the 3585. I read the service manual last night, and it sure as hell looks like there is a "digital link" in there. Not that I am unhappy with the result.
Cheers Terry .
- Follow-Ups:
- Re: S-parameter test sets
- From: Joerg
- Re: S-parameter test sets
- References:
- S-parameter test sets
- From: Terry Given
- Re: S-parameter test sets
- From: Wes Stewart
- Re: S-parameter test sets
- From: Terry Given
- Re: S-parameter test sets
- From: Joerg
- Re: S-parameter test sets
- From: Terry Given
- Re: S-parameter test sets
- From: Wes Stewart
- Re: S-parameter test sets
- From: Terry Given
- Re: S-parameter test sets
- From: Wes Stewart
- Re: S-parameter test sets
- From: Terry Given
- Re: S-parameter test sets
- From: Joerg
- Re: S-parameter test sets
- From: keith
- Re: S-parameter test sets
- From: Joerg
- Re: S-parameter test sets
- From: Terry Given
- Re: S-parameter test sets
- From: Joerg
- S-parameter test sets
- Prev by Date: Re: S-parameter test sets
- Next by Date: Re: The truth about decibels
- Previous by thread: Re: S-parameter test sets
- Next by thread: Re: S-parameter test sets
- Index(es):
Relevant Pages
|