Re: differences between shunt and series voltage references?
- From: "PeteS" <ps@xxxxxxxxxxxxxxxxxxx>
- Date: 11 Jul 2005 03:55:24 -0700
Just to add another option...
I also like the National LM4120 for A-D references. I am using this as
a reference for an existing A-D subsystem (not high speed, I must admit
- system voltage monitoring in this application).
I am using the LM4120AIM5-4.1 which has the following specs:
180mV dropout at 1mA (worst case, typical = 120mV)
+/-5mA sink OR source
50ppm tempco
Output noise voltage 20uV p-p 0.1Hz - 10Hz, 36uV p-p 10Hz - 10kHz
Zo < 1 ohm for F < 10kHz ( at Iout = 1mA)
Comes in a nice SOT23-5 package.
Cheers
PeteS
.