Re: help replacing an old ac power transformer.



fotoobscura@xxxxxxxxx wrote:
Hi.  I have a very old transformer/power supply that blew that i'm
trying to replace.

All it says on the outer box is:

120vac
75 watts
50-60hz

The transformer has 4 leads...two reds and two blocks.

The transformer was made sometime between 1974-1979.



I went to Rat shack to buy a new transformer which has three blacks and
two yellows.  Based on the way the wiring *was* setup I rewired the
transformer to the new one and flipped it on..  Nothing..not even a hum
or anything.  The radio shack lists "center-tapped secondary" if thats
any help.

There is one black wire "loose" and I am unsure where it goes or if it
should go anywhere.  There's nowhere else for it to go unless its
supposed to also connect to the ground (the ground already existed for
the plug to the box the transformer is in).  Is that last wire a
ground?


Transformers can be made in almost infinite variety. We have to figure out the approximate output voltage and current rating of the old unit. We may get a clue of the voltage from the big electrolytic filter capacitor voltage rating after the bridge rectifier. The rectifiers or capacitor may also be bad. In fact, your transformer may be fine. Once the output voltage rating has been figured out, the current rating can be approximated based on the power rating. As a last resort (after you are absolutely sure the transformer is bad) would be to take it apart and count the turns on primary and secondary and compute the output voltage that way. The wire gauges are also an indication of the current rating needed.
.




Relevant Pages

  • Re: How hot should an LCD TV transformer get?
    ... I wonder if they are made for a mains voltage ... run off 12 volt DC or 240 AC, with a supplied transformer. ... Look at the TV power rating - divide power by volts to get current ... then look at the rating of the PSU. ...
    (uk.tech.digital-tv)
  • Re: Transformer flux imbalande solutions
    ... Then i saw that the rating was PMPO. ... I didn't know they used PMPO that long ago. ... amplifier -- good for over 300 real watts into any kind of load you want. ... average tube and SS amps is the output transformer. ...
    (sci.electronics.design)
  • Re: Blown primary, how to determine unknown secondary voltages of a mains transformer
    ... reasonable idea of the voltage of one 'unknown' secondary. ... The transformer I used was 240V with marked 2 separate secondaries ... Noting that for one secondary for this test transformer was rating 300V, ...
    (sci.electronics.repair)
  • Re: Transformer flux imbalande solutions
    ... Then i saw that the rating was PMPO. ... I didn't know they used PMPO that long ago. ... average tube and SS amps is the output transformer. ... There were 8 of them, not quite enough for all that dissipation, ...
    (sci.electronics.design)
  • Re: Calculating DC Output Current From Unregulated AC Transformer
    ... "Phil Allison"> ... ** Read the whole post before making silly replies. ... I am looking only for a free air rating. ... no idea what current I plan to run from any particular transformer, ...
    (sci.electronics.basics)