Re: sample & hold: maxima - minima
- From: Jim Thompson <thegreatone@xxxxxxxxxxx>
- Date: Fri, 21 Oct 2005 08:25:00 -0700
On Thu, 20 Oct 2005 12:16:46 -0500, sonos <sonos@xxxxxxxxxxxxx> wrote:
>Hi,
>
>a 10mV ac 1kHz signal, an analog integrator, and an 8 bit adc on a
>microcontroller.
>
>1. what is the best way to build a SH for:
>a. the peak of the ac signal
>b. the trough of the ac signal
>
>would this involve a standard SH, with diodes?
>
>thanks to any and all replies.
>
Thumb through "FullWaveRectifier.pdf" on the S.E.D/Schematics page of
my website for peak (or trough) detector ideas.
...Jim Thompson
--
| James E.Thompson, P.E. | mens |
| Analog Innovations, Inc. | et |
| Analog/Mixed-Signal ASIC's and Discrete Systems | manus |
| Phoenix, Arizona Voice:(480)460-2350 | |
| E-mail Address at Website Fax:(480)460-2142 | Brass Rat |
| http://www.analog-innovations.com | 1962 |
I love to cook with wine. Sometimes I even put it in the food.
.