Re: Frame ground vs. "neutral" for DC
- From: "Richard Henry" <rphenry@xxxxxxxx>
- Date: Mon, 5 Jun 2006 11:42:54 -0700
"John Larkin" <jjlarkin@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx> wrote in message
news:c9o882pnas2jsv0klkppdb9sbhef9jdvqp@xxxxxxxxxx
On Mon, 05 Jun 2006 16:32:17 GMT, Ignoramus11409
<ignoramus11409@xxxxxxxxxxxxxxxxxxxx> wrote:
I have a welder with a bunch of DC electronic parts (5v, +/-12V), as
well as with some 120VAC components.
Obviously, good practice calls for separating ground from neutral for
120VAC equipment.
My question is, should I isolate GND for 12V, 5V etc equipment, or can
I just use equipment frame as ground?
thanks
i
For emi protection (which you sure as heck need) bolt everything to
frame ground as often as possible, and hard ground cable shields at
both ends. Multilayer boards with a solid internal ground plane help
greatly, and don't even think about separating analog and digital
grounds.
There seem to be 2 schools of thought on that last item.
.