Re: AD7714 help
- From: "Arlet" <usenet+5@xxxxxxxxxxxxxxxxx>
- Date: 16 Nov 2006 03:34:12 -0800
Prakruthi wrote:
I did compare the signals with the clock and found out that the data is
not getting transferred on the right clock edge. How do I set the clock
sync right. How do I determine what the right clock frequency for the SPI transfer
would be.
I m using the ATMega8 to communicate with the AD7714. So it has amazing
options for configuring the SPI clock frequency. The ATMega8 runs at a
frequency of 14.567MHz. And im using a SCLK frequency of fclkin/128 to
drive the slave(AD7714), with a CPOL=1 and CHPA=1. I have no idea what
the problem could be , cause I have tried all the different SCLK
frequencies that are available.
The clock frequency is within limits, and CPOL=1, CHPA=1 is also
correct.
What makes you say the 'data is not getting transferred on the right
clock edge' ?
.
- Follow-Ups:
- Re: AD7714 help
- From: Prakruthi
- Re: AD7714 help
- From: Prakruthi
- Re: AD7714 help
- References:
- AD7714 help
- From: Prakruthi
- Re: AD7714 help
- From: Arlet
- Re: AD7714 help
- From: Prakruthi
- Re: AD7714 help
- From: Arlet
- Re: AD7714 help
- From: Prakruthi
- Re: AD7714 help
- From: Arlet
- Re: AD7714 help
- From: Prakruthi
- AD7714 help
- Prev by Date: Re: Open Source Electronic Design Software
- Next by Date: Re: What types of circuits give rise to Singular martices?
- Previous by thread: Re: AD7714 help
- Next by thread: Re: AD7714 help
- Index(es):