Re: Looking for a 20 Bit DAC for Industrial Control
- From: Chris Smolinski <cps@xxxxxxxxxxxxxxxxxxx>
- Date: Fri, 02 Mar 2007 14:27:42 -0500
In article <2PadncZJafvO33jYnZ2dnUVZ8tChnZ2d@xxxxxx>,
"MK" <nospam@xxxxxxxxxx> wrote:
I have used DAC1220 (Burr Brown from TI) (a pair simulating a load cell in a
functional tester). No huge issues. They are sigma delta but not audio -
they quote settling time as 2mS so your 1kHz may be a little high.
Hi Michael,
Thanks for the info.
I see they quote a settling time of 10 msec for 20 bit mode, and 2 msec
for 16 bit mode. Have you found it to really be 2 msec for 20 bit mode?
I see the settling time is for large signal changes, most likely I will
be making small changes in normal operation.
--
---
Chris Smolinski
Black Cat Systems