Re: astable 555



On Wed, 13 Jun 2007 09:53:34 -0700, ejleiss@xxxxxxxxxxxxxxxx wrote:

I am trying to trigger an astable 555 oscillator using another 555 in
the monostable mode. Everything I see says that the astable 555 is
free-running. Is there a way to trigger it using the monostable?

--- _____
Connect the output of the monostable to the RESET input of the
astable. The astable will run while the monostable's output is
high.


--
JF
.



Relevant Pages

  • Re: astable 555
    ... free-running. ... Is there a way to trigger it using the monostable? ... Connect the output of the monostable to the RESET input of the ... the delay. ...
    (sci.electronics.design)
  • astable 555
    ... I am trying to trigger an astable 555 oscillator using another 555 in ... the monostable mode. ... free-running. ... Is there a way to trigger it using the monostable? ...
    (sci.electronics.design)
  • Re: astable 555
    ... the monostable mode. ... free-running. ... Is there a way to trigger it using the monostable? ... 555 shouldn't need a triger to start working. ...
    (sci.electronics.design)
  • Re: astable 555
    ... the monostable mode. ... free-running. ... Is there a way to trigger it using the monostable? ... View in a fixed-width font such as Courier. ...
    (sci.electronics.design)
  • Re: astable 555
    ... the monostable mode. ... free-running. ... Is there a way to trigger it using the monostable? ... you can use the reset pin to stop or start it. ...
    (sci.electronics.design)