You will probably have a transformer inside the cabinet. Imagine your
transformer has 100pF between Primary live and secondary (that is -
j32MOhm). This means that at 1500Vac, the current will be max 47uA.
** No so if there are any Y caps from the AC supply input to chassis
ground.
Values up to 4700 pF are allowed.
..... Phil
.