Re: Transformer question

From: philo (philo_at_privacy.net)
Date: 09/25/04


Date: Sat, 25 Sep 2004 12:35:41 -0500

T N Nurse wrote:
> I have a 50 watt valve amp which seems to have blown its
> output transformer. A new one is on order, but I was puzzled
> by some of the reading I got off it and wondered if someone
> could give an explanation. All the measurements were made
> with the transformer *_completely out of circuit_*, both primary
> and secondary.
>
> The transformer is from a push-pull standard guitar amp (Trace
> Elliot 50 watt combo, 2 EL34s) and one of the valves was glowing
> red hot before the fuse popped. Checking the bias voltages, I
> had around -46v on the grid of each of the El34s, so that was
> a reasonable figure. I then removed the output transformer
> and did some resistance measurements on it. When measure from
> the centre tap to either of the primary outer connections, the
> reading was 69 ohms for each. But when I measured across the
> primary outer connections, instead of the expected 138 ohms,
> I got an open circuit. I rechecked it numerous times but with
> the same result. I even removed the cables from their connector
> and measure across the bare wires, but still the same result,
> 69 ohms from the centre tap to the outers, but open circuit
> between the outers.
>
> On the basis of these bizarre reading, I assumed the transformer
> is faulty and ordered a new one, but can anyone offer an
> explanation as to why I got such resistance readings? I have a
> vague recollection of similar results on a small 15 watt amp I
> repaired many years ago and replacing the transformer fixed it
> and it went on to give good service, but I would like to know
> what is actually going on. Anyone?

there are usually two wires in the center tap...
if they are not touching when you take your reading ...there will be
infinite resistance...



Relevant Pages

  • Problem solved (Was: Transformer question)
    ... solved - intermittent fault in the probe lead. ... > The transformer is from a push-pull standard guitar amp (Trace ... > the centre tap to either of the primary outer connections, ... > reading was 69 ohms for each. ...
    (sci.electronics.misc)
  • Problem solved (Was: Transformer question)
    ... solved - intermittent fault in the probe lead. ... > The transformer is from a push-pull standard guitar amp (Trace ... > the centre tap to either of the primary outer connections, ... > reading was 69 ohms for each. ...
    (sci.electronics.repair)
  • Re: Transformer question
    ... >Having an open resistance reading on the primary in indicative there ... valve may have damages along with the transformer. ... > the centre tap to either of the primary outer connections, ...
    (sci.electronics.misc)
  • Re: Transformer question
    ... >Having an open resistance reading on the primary in indicative there ... valve may have damages along with the transformer. ... > the centre tap to either of the primary outer connections, ...
    (sci.electronics.repair)
  • Re: Transformer question
    ... > The transformer is from a push-pull standard guitar amp (Trace ... > the centre tap to either of the primary outer connections, ... > reading was 69 ohms for each. ...
    (sci.electronics.misc)

Loading