Re: Rheem heater/cooler does not turn off. Model RRGG-05N24JKR 230V 24A 3/1/1990
From: Phil Scott (philscott888_at_sf.sbcglobal.net)
Date: 12/16/04
- Next message: sofie: "Re: EP Bad audio....SP good audio HELP"
- Previous message: stokesb_at_cox.net: "Hitachi with green dot"
- In reply to: Leroy Mowry: "Rheem heater/cooler does not turn off. Model RRGG-05N24JKR 230V 24A 3/1/1990"
- Next in thread: NSM: "Re: Rheem heater/cooler does not turn off. Model RRGG-05N24JKR 230V 24A 3/1/1990"
- Reply: NSM: "Re: Rheem heater/cooler does not turn off. Model RRGG-05N24JKR 230V 24A 3/1/1990"
- Messages sorted by: [ date ] [ thread ]
Date: Thu, 16 Dec 2004 00:06:20 GMT
"Leroy Mowry" <@c.edu> wrote in message
news:RyPsd.54975$QJ3.36604@newssvr21.news.prodigy.com...
> My residential roof heater/air conditioner unit does not
shut-off
> the fans when the heater is switch off at the controls.
Setting
> the thermostat to 0-degrees or opening the circuit at the
control
> won't turn off the heater fan, only the gas will shut off.
Shutting
> off the main power supply is the only way to turn it off.
Turning
> it off and on does not help, no clicking is heard from the
relays.
> Normally, it is timed for 1-3 minutes before the fans shuts
off,
> but it doesn't. When it does shuts off, I can hear a click
from
> the relay. The air conditioner works fine.What could be
wrong
> with the circuit?
the contracts are problably arc'd across and stuck on the
units 'fan control' or fan control relay. The fan control
has a bimetal probe that sticks into the furnace plenum and
holds the fan off until the plenum gets warm on the heat
cycle..(so you dont get cold air when the furnace first
starts)...then keeps the fan running after the gas valve goes
off until the plenum cools a bit.
That gismo is probably defunct.
Phil Scott
>
> Thanks
>
>
>
>
>
>
>
- Next message: sofie: "Re: EP Bad audio....SP good audio HELP"
- Previous message: stokesb_at_cox.net: "Hitachi with green dot"
- In reply to: Leroy Mowry: "Rheem heater/cooler does not turn off. Model RRGG-05N24JKR 230V 24A 3/1/1990"
- Next in thread: NSM: "Re: Rheem heater/cooler does not turn off. Model RRGG-05N24JKR 230V 24A 3/1/1990"
- Reply: NSM: "Re: Rheem heater/cooler does not turn off. Model RRGG-05N24JKR 230V 24A 3/1/1990"
- Messages sorted by: [ date ] [ thread ]
Relevant Pages
|