PTK169 B+ still high
- From: "Roy and Rosa" <rbeaty@xxxxxxxxxxxxx>
- Date: Thu, 2 Jun 2005 18:02:15 -0500
PTK169AV had shorted hv splitter.
I dont have repair manual. I checked other posts I could find on net.
I replaced the 4 caps around smps. B+ in standby is 168 volts and drops to
160 volts in run.
I adjusted the pot labeled B+ reg, the one under the black snap cover, It
made no effect on standby and only drops to 159 volt in run.
I used RCA caps for 15 and 39 uf caps...105 deg.C for the other 2.
What else should I look for? Is there a pot I missed for standby
adjustment?
Thanks
.
- Follow-Ups:
- Fixed : PTK169 B+ still high
- From: Roy and Rosa
- Re: PTK169 B+ still high
- From: oldfogie
- Re: PTK169 B+ still high
- From: dkuhajda
- Re: PTK169 B+ still high
- From: Art
- Re: PTK169 B+ still high
- From: dkuhajda
- Fixed : PTK169 B+ still high
- Prev by Date: Re: Is this a 100Hz artefact?
- Next by Date: Re: PTK169 B+ still high
- Previous by thread: Winbook laptop ?
- Next by thread: Re: PTK169 B+ still high
- Index(es):
Relevant Pages
|