etphonehm@xxxxxxxxx wrote:
A few years ago, when there were no tumblers availabe yet in the US
market, I had imported a French-made washing machine (Brandt) to the US
for energy and space-saving purposes.  The machine was designed to work
in 220V/50hz and N. America has 110V/60hz.  And as a mechanical
engineer, I was naive to think that as long as I had a 220V outlet in
my house, the worst scenario would only be that the machine runs a
little faster (20%) which amounts to 24 minutes in a 120-min wash
cycle.

Well, as it turned out, the machine runs a lot faster.  The timing knob
finished a 120-min cycle in something like 6 minutes.  The wash, drain,
rinse and spin all were cut short within each function.  To this day, I
am still puzzled and not able to solve the problem.  If anyone could
shed any light on this subject, I would greatly appreciate it.

The only other possible cause would be a defective timer which could
have been assembled with fewer gear sets than ought to be.  But without
knowing for sure the root of the problem, it doesn't make sense for me
to invest another $100 to buy a timer from oversea with no English
service manual available.


A possibility is that the timer has developed a fault in that the gear set in the timer is somehow sticking. Most washing machine timers have a sytem where the main cam increments one notch for every so many revolutions of the timer motor. You might notice two 'barrels' inside, the rear one turning continously and the other clicking round once every revolution of the rear barrel. The rear barrel controls the main motor, and the front barrel the fill valves, drain pump and heater. Some machines have a solenoid which kicks the front barrel out of gear for certain parts of the wash - heat pause etc. This solenoid is controlled by a triac on the control module, maybe that`s where the problem lies. A continuously buzzing solenoid usually means a faulty module.


I,ve seen timers that clicked through in minutes because the little planet gears were gummed up with deteriorating grease.

Hth

Ron(UK)

--
Lune Valley Audio
Public address system
Hire, Sales, Repairs
www.lunevalleyaudio.com
.



Relevant Pages

  • Re: I need a way to open & close a solenoid activated valve at 1 - 5 second intervals.
    ... Howdy Dan! ... to the TB will be continuous feed, thus the need for the timer.. ... I want the solenoid valve to interrupt the water flow so the TB can ... Use an interval or repeat cycle timer, ...
    (alt.coffee)
  • Re: I need a way to open & close a solenoid activated valve at 1 - 5 second intervals.
    ... Keep in mind that the maximum time the solenoid can be off is 10 seconds and the minimum time it can be on is 1 second. ... Note that you will have to provide a 24VDC power supply to run the timer. ... You can buy those at an electronic supply house or Grainger. ... In essence you need a double timer, one that waits to turn the solenoid on, and one that then waits to turn it off. ...
    (alt.coffee)
  • Re: Help me solve this design problem PLEEEZ
    ... the timer counts down to zero and stays there. ... If the operator isn't paying attention, and he goes over 5 minutes, an alarm sounds to alert him that he is operating the electromagnet outside its design parameters. ... Or do you want a timer that locks out the solenoid for a duration equal to the preceding on time? ... you DO NOT EVER WANT TO INTERFACE WITH THE MAGNET IN ANY WAY!!! ...
    (sci.electronics.design)
  • Re: dishwasher drain solenoid melting. causes?
    ... the timer only allows the drain to work for 1 minute. ... hangs up, the solenoid will burn/melt. ... to the solenoid after about 70 seconds. ... You're right about the intermittent duty on the drain; ...
    (alt.home.repair)
  • Re: modernization of FORTH, Age Results
    ... William James wrote: ... (Washing Machine Application) HEX ... And TIMER isn't even used. ...
    (comp.lang.forth)

Loading