This 28 year old Stanley Vemco automatic gate uses mechanical relays.
hear aproblem is that the relays are noisy when either the opening or closing
sensor switches are activated at the end of its travel. For example,
somebody runs over the air hose to begin the open operation. You can
isrelay click with no problem, then the gate opens. Just before the gate
motorfully open, it enables a sensor switch which interrupts power to the
whichrelay. Then, you can hear one of the relays make a chattering noise
closes. Itdecays in about two seconds. The same thing happens when the gate
AC,seems to have gotten louder over the years. Since the entire circuit is
You've got a bad pair of contacts feeding the coil of one of the
relays. The chattering relay is probably not the one that is at
fault; the difficulty might well lie in that sensor switch. I've had
difficulties with magnetic reed switches in the past, and if there's
one there I would see about it. There may also be a bad connector
associated with the sensor switch. Find the wires that go to the
sensor switch and use a jumper across them to simulate the operation
of that switch. If the relays operate but do not chatter, then the
difficulty lies in the sensor switch or its wiring.
M Kinsler
The sensor switches are regular microswitches. I'll do the jumper test and
see what happens.
Thanks for the good suggestion.
--
David Farber
David Farber's Service Center
L.A., CA
.
- References:
- Old automatic gate controller question.
- From: David Farber
- Re: Old automatic gate controller question.
- From: m kinsler
- Old automatic gate controller question.
- Prev by Date: advise on best capacitor types for speaker cross-overs and where to buy
- Next by Date: Re: Strange problem with low energy light bulb
- Previous by thread: Re: Old automatic gate controller question.
- Next by thread: Panasonic TV
- Index(es):
Relevant Pages
|