Selenium rectifier question
- From: EricM <ew_morr@xxxxxxxxxxx>
- Date: Fri, 11 Apr 2008 14:19:39 -0700 (PDT)
I have replaced two old Federal/ITT selenium rectifiers in an
amplifier power supply with new silicon diodes; the original part
numbers are 103H4AX1 and 104B1AX1. I can't find any reference to
either part on the web - anywhere - ITT can't even provide
information. Since one of the legs of the circuit supplies the plate
voltage (600V) I used 600V 10A diodes (NTE5815HC) to be safe. Problem
is, there is a time-delay relay that closes to engage the 600V
circuit, and without it attached to the amp; all tube supplies,
biasing voltage, etc. are normal. If hooked up, once the relay closes
- the main power fuse blows. I'm guessing I need a dropping resistor,
but it would be nice to have the original data on the selenium parts
to be able to figure out the value. The 600V and the -38V biasing
voltage are derived from the same part of the power transformer. The
-38 side works, but the 600V side reads upwards of 927 volts without a
load. Using a Variac, the plate voltages were above 600V at about 70
percent. Is there a way to find the original specs on these selenium
parts? Any leads would be greatly appreciated!
.
- Follow-Ups:
- Re: Selenium rectifier question
- From: Jerry G.
- Re: Selenium rectifier question
- From: Pilgrim
- Re: Selenium rectifier question
- From: Michael A. Terrell
- Re: Selenium rectifier question
- From: Peter Dettmann
- Re: Selenium rectifier question
- From: PeterD
- Re: Selenium rectifier question
- Prev by Date: Re: CRT Giveaway
- Next by Date: Re: Selenium rectifier question
- Previous by thread: Bud Abbott and Lou Costello.
- Next by thread: Re: Selenium rectifier question
- Index(es):