Re: Intermittent fault in Eizo 19" T766 CRT



Wiebe Cazemier wrote:

On Monday 28 April 2008 19:00, James Sweet wrote:


Yep, sounds like it really is the tube. If it's a heater-cathode short, you
could isolate the heater, powering it with 2 or 3 turns of wire around the
flyback core. Careful not to overdo it, it really only takes a couple of
turns on these high frequency transformers.


Indeed, I read about that. The downside is, that image quality will suffer,
because the cathode will/can be in contact with those wires, which have stray
capacitance, and noise pickup, etc.

Additionally, I don't know if the Trinitrons feature of automatic color
calibration touches the filament current, but if so, that will render that
feature useless, and it's a feature I love about this monitor. Do you know if
it does so?

But I will try the shake/tap method a bit more first. The short is every so
slight, that even after 20 seconds of warming up, the fault is almost
completely gone and hardly reproduceable. I wonder if it also does it when
it's upside-down...
why not use a isolation xformer for the heaters?


--
"I'd rather have a bottle in front of me than a frontal lobotomy"

"Daily Thought:

SOME PEOPLE ARE LIKE SLINKIES. NOT REALLY GOOD FOR ANYTHING BUT
THEY BRING A SMILE TO YOUR FACE WHEN PUSHED DOWN THE STAIRS.
http://webpages.charter.net/jamie_5";

.



Relevant Pages

  • Re: PT shorted in JTM45
    ... After checking to make sure the fuses were in the right holders and everything was soldered together I plugged in the AC and hit the mains switch. ... Next I started to look at my grounds and check every wire that ran past them, all insulation looked intact and no burnt spots. ... I looked at all the tube sockets with a flashlight and inspection mirror and could not find any grounds where there where not supposed to be, so I checked the heater wires from the first tube to the tranny. ...
    (alt.guitar.amps)
  • Re: PT shorted in JTM45
    ... After checking to make sure the fuses were in the right holders and everything was soldered together I plugged in the AC and hit the mains switch. ... Next I started to look at my grounds and check every wire that ran past them, all insulation looked intact and no burnt spots. ... I looked at all the tube sockets with a flashlight and inspection mirror and could not find any grounds where there where not supposed to be, so I checked the heater wires from the first tube to the tranny. ...
    (alt.guitar.amps)
  • Re: PT shorted in JTM45
    ... After checking to make sure the fuses were in the right holders and everything was soldered together I plugged in the AC and hit the mains switch. ... Next I started to look at my grounds and check every wire that ran past them, all insulation looked intact and no burnt spots. ... I looked at all the tube sockets with a flashlight and inspection mirror and could not find any grounds where there where not supposed to be, so I checked the heater wires from the first tube to the tranny. ...
    (alt.guitar.amps)
  • FreshRoast heater kill-switch
    ... cut the heater wire to my roaster. ... to the fan and the heater. ... switch to the two cut pieces of heater element wire. ...
    (alt.coffee)
  • Re: Troubleshooting garage door opener
    ... Any idea how I can isolate the ... I'm not much of an electrician. ... Disconnect the wire at the opener. ...
    (alt.home.repair)