Re: unkown output impedance measurement?
- From: "Charles" <charlesschuler@xxxxxxxxxxx>
- Date: Sun, 2 Nov 2008 17:47:03 -0500
"Henry Kolesnik" <kolesnik@xxxxxxxxxxxxxxxxxxx> wrote in message
news:Kj7Pk.6569$be.3512@xxxxxxxxxxxxxxxxxxxxxxx
What the easiest ways to measure the output impedance of a push pull tube
amplifier?
Load the amplifier with an adjustable resistor. When the loaded output
voltage drops to 1/2 of the no-load voltage, the resistor can be removed and
measured with an ohmmeter.
.