Re: Solar breakthrough - when?

From: Don Lancaster (don_at_tinaja.com)
Date: 08/19/04


Date: Thu, 19 Aug 2004 09:21:54 -0700


"Fred B. McGalliard" wrote:
>
> "Don Lancaster" <don@tinaja.com> wrote in message
> news:41241C97.AED09444@tinaja.com...
> ...
> > The T's, of course, are ABSOLUTE TEMPERATURE. A 70 degree F source with
> > a 50 degree F sink would have a theoretical maximum efficiency of 1 -
> > 523/543 or well under FOUR PERCENT. A real world system could not
> > possibly do this good.
>
> Perfectly true, except the high temp may be a bit closer to 80F during the
> warm summer and the low is a bit closer to 40F (just a bit above 4C I think,
> below which cold water rises instead of sinking..
> Also, the heat collector for this is pretty much free, so the only problem
> is how much it costs to make a turbine that will run with these low
> temperatures, and how much it costs to build the warm/cold water heat
> exchangers. The OTEC project has used some really bright ideas to reduce
> loss from heat exchangers and such. I saw the plant in Hawaii, just south of
> Kona on the big island. If I had had more time, I would have tried to get a
> tour. I don't recall if the plant is still operating but there are still
> folk there.
>
> > Before amortization and fully burdened cost accounting.
>
> AAAAARRRRRRRRGGGGG. Nuf said.

The usual problem is the delta T's of the coupling heatsinks or
mechanisms between ambient and the process. On both ends. It is tricky
to get under 0.3 degrees per watt.

Ferinstance, if you try running Peltier at more than a few watts, the
delta T across your heatsink EXCEEDS your net cooling.

-- 
Many thanks,
Don Lancaster
Synergetics   3860 West First Street  Box 809  Thatcher, AZ 85552
voice: (928)428-4073 email: don@tinaja.com   
Please visit my GURU's LAIR web site at http://www.tinaja.com


Relevant Pages

  • Re: Use of Extension Cord
    ... I watch what I please and if I don't like it I mute it. ... An AC just MOVES the heat. ... Or 5.29 watt hours moved for each watt hour consumed. ... No dumbass, gas-guzzling has nothing to do with it, and from what I see on the street, there aren't huge numbers of gas-guzzlers around. ...
    (sci.electronics.basics)
  • Re: Price of Light Bulbs
    ... even cut the cooling costs in summer time (going from 3000 to 5000 or more watts of heat from lamps to 300 to 500 watts of heat from CFs) ... I surely think that sales of 23 watt compact fluorescents will increase if they are advertised as meeting/exceeding 75 watt incandescent and 100 watt extended-life incandescent as opposed to being often found half a ... i have fixtures that I want to put a brighter lamp into, but lamp length cannot exceed 5 inches. ...
    (alt.home.repair)
  • Re: Vector 3,000 watt power inverter question
    ... if you're looking for heat, even a fully charged newcar battery ... from the battery at that kind of load. ... but a 9 watt florescent will run ...
    (sci.electronics.repair)
  • Re: Price of Light Bulbs
    ... more watts of heat from lamps to 300 to 500 watts of heat from CFs) ... I surely see the good points of compact fluorescents, ... I surely think that sales of 23 watt compact fluorescents will increase ... if they are advertised as meeting/exceeding 75 watt incandescent and 100 ...
    (alt.home.repair)
  • Re: Portable Furnace
    ... A 1500 watt "furnace" is nothing more than a space heater. ... There is nothing magical about using light bulbs to heat a heat exchanger. ...
    (alt.home.repair)