Re: copper-graphite connections



On Tue, 30 Aug 2005 12:53:24 +0100, Steve <Steve@xxxxxxxxxxxxxx>
wrote:

>Hi,
>Does anyone have experience of making very low resistance
>copper-graphite fixed connections ? Is there anything I should use to
>coat the interface to minimise the resistance ? I am just using "naked"
>graphite and OFHC copper, with screws to clamp a copper washer on top of
>the sandwich. At 350A, I am dropping around 300mV, which is around 1
>milliOhm, with a contact area of around 2 sq inch (~1300 mm^2)
>
>Is one milliohm good ?

Not for 2sq"
Try putting some conductive silver paste between, and see what you
get.
.



Relevant Pages

  • copper-graphite connections
    ... Does anyone have experience of making very low resistance copper-graphite fixed connections? ... Is there anything I should use to coat the interface to minimise the resistance? ... I am just using "naked" graphite and OFHC copper, with screws to clamp a copper washer on top of the sandwich. ...